R&D Report 1993-06 : Metal-framed partitions with reduced thicknesses: Part 2 -- Built-in acoustic treatment. G.D. Plumb Laboratory measurements were made of the sound insulations and absorption coefficients of a range of metal-framed partitions having built-in acoustic treatment. The optimum constructions for single and double leaf absorbent partitions had marginally lower sound insulations (approximately 1 dB) than those of comparable single and double metal-framed Camdens. The effective...
Topics: partitions, absorption, partition, sound, insulation, unperforated, perforated, leaf, acoustic,...
R&D Report 1993-05 : Metal-framed partitions with reduced thicknesses: Part 1 -- Narrower studs and cavities. G.D. Plumb The sound insulations were measured, in the Research Department Transmission Suite, of ten different metal-framed partitions. These partitions had narrower cavities and metal studs than those of the conventional thickness metal-framed Camden. Mineral wool had been installed in the cavities of some of the partitions and some partitions had double plasterboard skins rather...
Topics: sound, partitions, partition, studs, mineral, leaf, insulations, insulation, plasterboard, double,...
R&D Report 1995-07 : Further investigations of partitions having built-in acoustic treatment. G.D. Plumb Laboratory measurements were made of the sound insulations and absorption coefficients of a range of metal-framed partitions having built-in acoustic treatment. The partitions were made using glass wool and gypsum boards. The sound insulations of the single leaf partitions having built-in acoustic treatment were considerably lower than those of comparable partitions made using mineral...
Topics: partitions, mineral, partition, glass, insulations, unperforated, perforated, wool, absorption,...